Every instrument, calibrated on schedule, with the certificate attached to the record.

Calibration Management tracks calibration intervals for instruments and equipment, escalates before a due date is missed, stores certificates directly against the equipment record, and can open an investigation automatically when a result comes back out of tolerance.

21 CFR §211.68 21 CFR §211.63 EU GMP Annex 15
Back to platform overview
Regulatory basis

Calibration status is one of the first things an investigator checks.

An out-of-calibration instrument can call every result it produced into question — which is why calibration status has to be provably current, not just assumed.

21 CFR §211.68

Automatic, Mechanical & Electronic Equipment

Requires such equipment to be routinely calibrated, inspected or checked according to a written program, with records of those checks maintained.

21 CFR §211.63

Equipment Design, Size and Location

Equipment must be of appropriate design and suitably located to facilitate the calibration, cleaning and maintenance operations §211.68 requires.

EU GMP Annex 15

Qualification & Validation

Instrument calibration status is a prerequisite input to equipment qualification (IQ/OQ/PQ) — a lapsed calibration can invalidate a qualified state.

NOTE The module manages scheduling, escalation and evidence storage. Setting the correct calibration interval and tolerance for each instrument remains an engineering and QA decision.
Why teams use GxP Technology

Calibration that escalates before it's missed, not after.

A missed calibration is rarely a surprise in hindsight — it's a reminder that didn't reach the right person in time.

Due dates calculated automatically

Calibration intervals are calculated from each instrument's master data — no separate spreadsheet to keep in sync.

Escalation before the deadline

Reminders fire ahead of the due date and escalate if unacknowledged, instead of surfacing the miss only after it's already happened.

Certificates live on the equipment record

Calibration certificates attach directly to the instrument's record, so there's one place to look during an audit, not a filing cabinet to search.

Out-of-tolerance triggers an investigation

An OOT result can open an investigation directly from the calibration record, without switching to a separate system to start it.

See calibration scheduling and OOT handling live.

We'll show interval scheduling, escalation, certificate storage and the out-of-tolerance investigation trigger using an instrument type from your own site.